Crowcon I-Test Automated Portable Gas Detector Test Station, 1 x Gas Inlet and Gas Pro Module for UL Regional Settings (CH4 set to 2.5%), with C03332 Regulator and AC0510 Cylinder Holder - IT-GP-11Z-ZB-K

  • Crowcon I-Test Automated Portable Gas Detector Test Station, 1 x Gas Inlet and Gas Pro Module for UL Regional Settings (CH4 set to 2.5%), with C03332 Regulator and AC0510 Cylinder Holder - IT-GP-11Z-ZB-K
  • Crowcon I-Test Automated Portable Gas Detector Test Station, 1 x Gas Inlet and Gas Pro Module for UL Regional Settings (CH4 set to 2.5%), with C03332 Regulator and AC0510 Cylinder Holder - IT-GP-11Z-ZB-K
  • Crowcon I-Test Automated Portable Gas Detector Test Station, 1 x Gas Inlet and Gas Pro Module for UL Regional Settings (CH4 set to 2.5%), with C03332 Regulator and AC0510 Cylinder Holder - IT-GP-11Z-ZB-K
  • Crowcon I-Test Automated Portable Gas Detector Test Station, 1 x Gas Inlet and Gas Pro Module for UL Regional Settings (CH4 set to 2.5%), with C03332 Regulator and AC0510 Cylinder Holder - IT-GP-11Z-ZB-K

Item #
IT-GP-11Z-ZB-K
Price
$3,237.00
Quantity
Send Page to Friend

IT-GP-11Z-ZB-K I-Test Automated Portable Gas Detector Test Station, 1 x Gas Inlet and Gas Pro Module for UL Regional Settings (CH4 set to 2.5%), with C03332 Regulator and AC0510 Cylinder Holder by Crowcon

I-Test is Crowcon's newest solution to test and verify that your Gas-Pro and T4 are in a compliant state to carry out your daily work. Bump testing standards are getting tighter in all regions and the need for controlled bump and calibration records is a must. I-Test and the accompanying I-Test Manager software makes this as easy as can be.

It takes less than 1 minute to complete a bump test with I-Test

Flexible

  • Mains powered, or battery back-up - Allows you to use on site, or in field
  • Entirely self-contained - No extra computers or equipment required
  • Ability to update Gas-Pro and T4 configurations - Update the bump test interval or alarm levels of your fleet with ease and no fleet downtime
  • Data management - Archive gas level data from detectors long term
  • Powerful support software - Makes configuring I-Test to site requirements extremely easy

Reliable

  • I-Test recognises empty or expired cylinders - Allows for planned refills and no unit downtime
  • Testing starts automatically when detector is inserted - Minimal user training required
  • Ensures the audible and visual alarms are working - Gives the user full confidence that the Gas-Pro is compliant to use
  • Battery backup - Testing continues even if power is out

Records

  • Everything is logged - See everything that has been tested and whether it has passed/failed
  • Exception reporting - Precise reports flag up who has and hasn’t carried out their bump test or calibration
  • Powerful reporting - Need to see which detectors have gone in to alarm in the last month? I-Test Manager makes easy work of pulling report summaries together



Size 110 x 250 x 320mm (4.3 x 9.8 x 12.6 ins)
Weight 2kg (70.5oz)
Input Supply 9-12V @ 3A
I-Test backup battery 200 speedy bump tests with 15-second intervals between tests
5 hours in standby with no bump test
Battery life approximately 500 cycles
Charge time 7 hours
RTC backup battery 3-year life
USB interface One standard USB type A socket for USB Flash Memory stick
One standard USB type B socket for connections to PC
Inlets/Outlets Single gas inlet (requires demand flow regulator)
Purge inlet (air)
Exhaust
Regulators Demand flow regulator required
Storage capacity Internal 2GB MicroSD card
Temperature specifications Operating temperature: -10°C to +50°C
Storage temperature: -25°C to +60°C
Charging temperature: 0°C to +40°C
Humidity 0% and 95% relative humidity (non-condensing) at +40°C
Ingress protection IP20